Orthokeratology for Astigmatism: Now Available

Orthokeratology, a method of myopia correction without surgery, was introduced at our clinic in the spring of 2019.
Many people so far have been able to obtain clear unaided vision without surgery.
However, it was difficult to apply to patients with strong astigmatism.

With the arrival of a new custom-order lens, Breath-O Correct® TD, orthokeratology treatment has become possible even for patients with strong corneal astigmatism.

We have been able to offer a new treatment option to patients with strong astigmatism, for whom conventional orthokeratology was difficult.

オルソケラトロジーのしくみの図:装用前は焦点が網膜の手前にあるが、就寝時にレンズを装用して角膜の形を矯正することで、装用中・装用後(レンズを外した後)は焦点が網膜上に合うことを示す3つの眼球断面図
TOC

What “Astigmatism” Really Means, Often Misunderstood

The meaning of astigmatism may differ from the image people have of it.

Astigmatism is a condition in which the shape of the cornea (the black part of the eye) is distorted.

The word tends to give the impression that things “look disordered,”
but in fact it is a refractive error that arises because the curvature of the cornea and the lens differs depending on the direction.

正視と乱視の比較図解(日英併記):正視では光が網膜上の1点に集まりAの文字がはっきり見えるが、乱視では角膜のゆがみにより焦点が複数に分かれ、Aの文字が二重にぼやけて見えることを眼球断面図で示す

The cornea is originally shaped like a sphere, but when astigmatism is present it is shaped more like an ellipse or a rugby ball.

Everyone has some astigmatism, but what matters is astigmatism of a degree that needs correction.

乱視の眼球断面図:角膜がゆがんだ状態で焦点が複数に分かれることと、円柱レンズで矯正することを示す。矯正できない乱視は円錐角膜の可能性があるとの注記と目の写真つき

(Corneal topography sometimes reveals keratoconus.)

What Is Breath-O Correct® TD?

Breath-O Correct® TD is a custom-order orthokeratology lens used for patients with strong corneal astigmatism (1.50 D or more as a guide).

Its lens design has been devised for patients in whom stable wear was difficult with the conventional Breath-O Correct® (BOC).

Differences from the conventional lens

トーリックデザインのオルソケラトロジーレンズの構造イメージ図:ベースカーブ・リバースカーブ・フィッティングカーブ・ペリフェラルカーブと、強主経線・弱主経線に合わせたトーリックデザインを示す

Conventional orthokeratology lenses have a spherical design, whereas Breath-O Correct® TD has the following:

  • A toric design (a shape that differs by meridian) in the area outside the reverse curve
  • The optic zone remains spherical
  • The design of the flat and steep principal meridians follows that of the conventional product

With this design, the stable position of the lens is improved even in patients with large corneal astigmatism.

Who it is for

Breath-O Correct® TD is intended for people who meet the following conditions:

Main conditions

乱視眼の角膜形状解析画像とハードコンタクトレンズの断面模式図:角膜形状が部分的または全体的にラグビーボール状(乱視)の場合のレンズフィッティングを示す(ブレスオーコレクトTD)
  • Corneal astigmatism of 1.50 D or more (see the keratometry values)
  • The corneal astigmatism extends to the periphery
  • Myopia: -1.00 D to -4.00 D
  • Cylinder power is no more than half of the spherical power

Certified orthoptistsperform the eye examinations and take the measurements.

角膜形状解析装置の画像の見方の図解:カラーマップは暖色系(赤)ほどカーブがきつく、寒色系ほどフラット気味であることを示す

Steep and Flat Meridians: What the Astigmatism Power (“Cylinder Power”) Means

In a cornea with astigmatism, the direction with the tightest curve is called the “steep meridian,” and the direction with the gentlest curve is called the “flat meridian.”

  • Steep meridian: the direction in which the corneal curve is steepest (stronger refractive power)
  • Flat meridian: the direction in which the corneal curve is flattest (weaker refractive power)

The difference in refractive power between these two meridians is the degree of astigmatism (cylinder power).
For example, if the steep meridian is 45.00 D and the flat meridian is 43.00 D, the astigmatism is 2.00 D.

視力表記の方法の図解:Vd(右眼視力)=0.1(1.2×S-2.00 C-1.50 Ax180°)の例で、裸眼視力・矯正視力・球面度数・円柱度数・円柱軸の読み方を示す

Orthokeratology for Astigmatism: What Is Important

Even if the corneal astigmatism is 1.50 D or more,
if the corneal astigmatism does not extend to the periphery, the conventional Breath-O Correct® (BOC) is used.

We examine the shape of the cornea in detail and confirm the distribution pattern of the corneal astigmatism.

角膜形状解析装置(NIDEK社)の写真:モニターに角膜のカラーマップ解析画面が表示されている
Corneal topographer / whole-eye refraction analyzer
OPD (Optical Path Difference) scan III (NIDEK)

How Treatment Proceeds

1. Initial examination and assessment of suitability

Using a corneal topographer, we measure the corneal curvature and the distribution of astigmatism in detail.

Based on the results, we determine whether Breath-O Correct® TD is suitable.

2. Determining the lens specifications

Depending on the patient’s situation, we calculate the lens specifications by one of the following methods:

When prescribing for the first time from unaided eyes

  • Fitting curve: use the flat meridian value
  • Target power: use the objective refraction value
  • Cylinder power: calculated as steep meridian minus flat meridian
  • Size: start with the standard size (10.6 mm)

When switching from a conventional orthokeratology lens

  • Use the keratometry values at the first visit and the information on the conventional lens
  • Calculate an appropriate specification with a formula

3. Checking the fit

We have also ordered a Breath-O Correct® TD trial lens (for in-clinic testing only, not for loan).
We also use conventional orthokeratology trial lenses to check the fitting in advance.

When Breath-O Correct® TD is actually worn, the physician checks the following points.
The cornea is stained with a fluorescein strip, and the state of the fit is observed.

  • The fluorescein staining pattern is an appropriate doughnut pattern
  • The lens is well centered
  • There is no air between the lens and the cornea
  • The lens moves about 1 to 2 mm with blinking
  • The width in the steep meridian direction stains slightly thicker than in the flat meridian direction

Warranty

Warranty conditions for Breath-O Correct® TD:

  • Warranty period: within 12 months of the shipping date of the new lens
  • Number of warranty replacements: up to 2 per eye (no distinction between prescription changes and breakage replacements)
  • Orders: up to 1 lens per eye

Orthokeratology for Astigmatism: Points to Keep in Mind

Clarifying the purpose of treatment

Breath-O Correct® TD is a lens to improve the stable position in patients with large corneal astigmatism.

It is not a lens intended to correct total astigmatism (refractive astigmatism).

Total astigmatism (refractive astigmatism) is the combination of lenticular astigmatism and corneal astigmatism.
Because orthokeratology is a treatment that changes the shape of the cornea, it is effective for corneal astigmatism but cannot correct lenticular astigmatism.

How much astigmatism is there? 
We use a corneal topographer / whole-eye refraction analyzer (NIDEK’s OPD-scan) to distinguish the type of astigmatism.

About the trial wear

Breath-O Correct® TD has no trial lenses available for loan.
During the one-week trial wear period, a conventional trial lens is used.

Sufficient explanation and examination at the fitting visit are very important.

The need to change specifications

If the fit with the first lens is inappropriate, specifications are changed after considering the following points:

  • Curve change: when the fit is steep or flat
  • Power change: when there is under-correction or over-correction
  • Cylinder power change: when fluorescein stains in the steep meridian direction
  • Size change: when inferior stabilization or horizontal deviation is seen

Summary

With the arrival of Breath-O Correct® TD,
a treatment option can now be offered even to patients with strong corneal astigmatism, for whom orthokeratology treatment had been difficult.

With detailed examinations and accurate calculation of specifications, good treatment results can be expected.

Patients who had given up on orthokeratology because of strong corneal astigmatism
may find it worth considering this new treatment option.

If you are considering treatment, it is important to undergo a detailed examination of the corneal shape and to receive a sufficient explanation.

Takeru Yoshimura, M.D., Ph.D.

たける眼科
takeru-eye.com
福岡市早良区「高取商店街」
西新駅/藤崎駅(福岡市地下鉄)

日本眼科学会 眼科専門医
医学博士(九州大学)

Takeru Yoshimura, M.D., Ph.D.

当ウェブサイトに掲載されている情報は、一般的な情報提供のみを目的としており、個別の医療アドバイスに代わるものではありません。ご自身の健康状態や治療に関するご質問は、必ず眼科専門医・医療専門家にご相談ください。

眼科で使う言葉:思っていた意味と、実際の意味

https://takeru-eye.com/blog/eye-clinic-words-misconceptions/

「症状」を“Googleする”:医療情報を正しくつかうために

https://takeru-eye.com/blog/04102021-never-google-your-symptoms/

目の炎症とは?

https://takeru-eye.com/ocularinflammation/

 

 

TOC